1.
Catheter Cardiovasc Interv
; 99(5): 1558-1562, 2022 04.
Article
in English
| MEDLINE | ID: covidwho-1850011
ABSTRACT
We report the first use of a single 100-mm long custom-made version of the Optimus-CVS® balloon-expandable PTFE-covered XXL (15-Zig) stent (AndraTec, GmbH) to eliminate sinus venosus defect left-to-right shunt and redirect anomalous right pulmonary veins blood flow through a new walled channel to the left atrium. Anatomical feasibility and strategy decision were guided by ex-vivo procedure simulation on the patient-specific 3D printed heart model and in-vivo balloon interrogation. Modified procedural and implantation techniques are detailed. Immediate and one-month follow-up showed excellent outcomes.
Subject(s)
Heart Defects, Congenital , Heart Septal Defects, Atrial , Pulmonary Veins , Vascular Malformations , Drainage , Humans , Pulmonary Veins/abnormalities , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Stents , Treatment Outcome
2.
Archives of Cardiovascular Diseases Supplements
; 13(4):271-271, 2021.
Article
in English
| PMC | ID: covidwho-1356101